Troubleshooting steps to perform when AP is not powering on by PoE

Summary

Steps to troubleshoot AP power issues, including switch port capabilities / total load, per number of AP power requirements.

Question

What are Troubleshooting steps to perform when AP is not powering on by PoE?

Customer Environment

ICX7250 24P R610

Root Cause

ICX does not correctly allocate PoE budget for the respective port when AP is using PoE injector.

Symptoms

"AP intermittently powering ON/OFF"


 Port   Admin   Oper    ---Power(mWatts)---  PD Type  PD Class  Pri  Fault/
        State   State   Consumed  Allocated                          Error
--------------------------------------------------------------------------
  1/1/1 On      On          5400      18000  802.3at  Class 4     3  n/a
  1/1/2 On      On          4700      18000  802.3at  Class 4     3  n/a
  1/1/3 On      Off            0          0  n/a      n/a         3  n/a
  1/1/4 On      On          5300      18000  802.3at  Class 4     3  n/a
  1/1/5 On      On          5100      18000  802.3at  Class 4     3  n/a
  1/1/6 On      On          4500      18000  802.3at  Class 4     3  n/a
  1/1/7 On      On          4800      18000  802.3at  Class 4     3  n/a
  1/1/8 On      On          5000      18000  802.3at  Class 4     3  n/a
  1/1/9 On      On          4700      18000  802.3at  Class 4     3  n/a
 1/1/10 On      On          4800      18000  802.3at  Class 4     3  n/a
 1/1/11 On      On          4700      18000  802.3at  Class 4     3  n/a
 1/1/12 On      On          5300      18000  802.3at  Class 4     3  n/a
 1/1/13 On      On          5100      18000  802.3at  Class 4     3  n/a
 1/1/14 On      On          4700      18000  802.3at  Class 4     3  n/a
 1/1/15 On      On          5100      18000  802.3at  Class 4     3  n/a
 1/1/16 On      On          4600      18000  802.3at  Class 4     3  n/a
 1/1/17 On      On          4600      18000  802.3at  Class 4     3  n/a
 1/1/18 On      Off            0          0  n/a      n/a         3  n/a
 1/1/19 On      Off            0          0  n/a      n/a         3  n/a
 1/1/20 Off     Off            0          0  n/a      n/a         3  n/a
 1/1/21 Off     Off            0          0  n/a      n/a         3  n/a
 1/1/22 Off     Off            0          0  n/a      n/a         3  n/a
 1/1/23 Off     Off            0          0  n/a      n/a         3  n/a
 1/1/24 Off     Off            0          0  n/a      n/a         3  n/a
--------------------------------------------------------------------------
 Total                     78400     288000

Troubleshooting Steps

Basic POE troubleshooting
  1. Check whether the Ethernet cable is connected to the proper PoE port of the AP or not.  Is it rated correctly for distance between switch/AP (Cat5/5e, Cat6/6a)?
  2. Try another port on the switch.
  3. Try a different cable if possible. Check the cable ends for damage, corrosion, etc.
  4. Check the switch configuration to ensure POE of the proper type is enabled. [ 802.3af (802.3at Type1 'PoE'), 802.3 at (802.3at Type2 'PoE+') ].
  5. Check the switch which you are using has PoE option or not. Also check the specific Ethernet port. Some of the switches will have PoE enabled for some specific Ethernet ports only.
  6. If practical, try another AP on the same switch port. If it powers up, first AP may have a bad AP PoE port (RMA).
  7. When multiple APs are connected to the PoE switch, Keep an eye on the PoE budget also. If the PoE budget of the switch is exceeded then the AP(s) will not get power from the Switch.
  8. Check whether the PoE output specification of the switch is compatible with the AP's PoE port or not, for example 802.3 af / 802.3at.

Note: These guidelines relate to all manufacturer PoE switches (not just ICX) and Ruckus APs.

Workaround

Apply PoE by class, class 4 for R610 model AP.


 

Resolution

Apply PoE by class, class 4 for R610 model AP.

Indoor R610 802.11ac Wave 2 3x3:3 WiFi Access Point Data Sheet:

https://ruckus-www.s3.amazonaws.com/pdf/datasheets/ds-ruckus-r610.pdf 

Power Supply........................Mode Features, Max Power consumption

DC input 12V DC, 2.0A.........Full Functionality, 19.1W

802.3af.................................Limits 2.4G to 2-chain,noUSB,1Eth port, 15W

802.3at.................................Full Functionality, 18.8W

Related Articles

KBA-8762: ICX7250-24P Providing PoE to Ruckus R610 AP

Article Number:
000001617

Updated:
April 30, 2021 02:04 AM (over 3 years ago)

Tags:
Installation, Troubleshooting, Ruckus ICX Switches, ZoneFlex Indoor, ZoneFlex Outdoor

Votes:
8

This article is:
helpful
not helpful

Working...Please wait

This is here to prevent you from accidentally submitting twice.

The page will automatically refresh.

Alert!!

Close