Troubleshooting steps to perform when AP is not powering on by PoE
Summary
Steps to troubleshoot AP power issues, including switch port capabilities / total load, per number of AP power requirements.Question
What are Troubleshooting steps to perform when AP is not powering on by PoE?Customer Environment
ICX7250 24P R610Root Cause
ICX does not correctly allocate PoE budget for the respective port when AP is using PoE injector.Symptoms
"AP intermittently powering ON/OFF"
Port Admin Oper ---Power(mWatts)--- PD Type PD Class Pri Fault/
State State Consumed Allocated Error
--------------------------------------------------------------------------
1/1/1 On On 5400 18000 802.3at Class 4 3 n/a
1/1/2 On On 4700 18000 802.3at Class 4 3 n/a
1/1/3 On Off 0 0 n/a n/a 3 n/a
1/1/4 On On 5300 18000 802.3at Class 4 3 n/a
1/1/5 On On 5100 18000 802.3at Class 4 3 n/a
1/1/6 On On 4500 18000 802.3at Class 4 3 n/a
1/1/7 On On 4800 18000 802.3at Class 4 3 n/a
1/1/8 On On 5000 18000 802.3at Class 4 3 n/a
1/1/9 On On 4700 18000 802.3at Class 4 3 n/a
1/1/10 On On 4800 18000 802.3at Class 4 3 n/a
1/1/11 On On 4700 18000 802.3at Class 4 3 n/a
1/1/12 On On 5300 18000 802.3at Class 4 3 n/a
1/1/13 On On 5100 18000 802.3at Class 4 3 n/a
1/1/14 On On 4700 18000 802.3at Class 4 3 n/a
1/1/15 On On 5100 18000 802.3at Class 4 3 n/a
1/1/16 On On 4600 18000 802.3at Class 4 3 n/a
1/1/17 On On 4600 18000 802.3at Class 4 3 n/a
1/1/18 On Off 0 0 n/a n/a 3 n/a
1/1/19 On Off 0 0 n/a n/a 3 n/a
1/1/20 Off Off 0 0 n/a n/a 3 n/a
1/1/21 Off Off 0 0 n/a n/a 3 n/a
1/1/22 Off Off 0 0 n/a n/a 3 n/a
1/1/23 Off Off 0 0 n/a n/a 3 n/a
1/1/24 Off Off 0 0 n/a n/a 3 n/a
--------------------------------------------------------------------------
Total 78400 288000
Troubleshooting Steps
Basic POE troubleshooting- Check whether the Ethernet cable is connected to the proper PoE port of the AP or not. Is it rated correctly for distance between switch/AP (Cat5/5e, Cat6/6a)?
- Try another port on the switch.
- Try a different cable if possible. Check the cable ends for damage, corrosion, etc.
- Check the switch configuration to ensure POE of the proper type is enabled. [ 802.3af (802.3at Type1 'PoE'), 802.3 at (802.3at Type2 'PoE+') ].
- Check the switch which you are using has PoE option or not. Also check the specific Ethernet port. Some of the switches will have PoE enabled for some specific Ethernet ports only.
- If practical, try another AP on the same switch port. If it powers up, first AP may have a bad AP PoE port (RMA).
- When multiple APs are connected to the PoE switch, Keep an eye on the PoE budget also. If the PoE budget of the switch is exceeded then the AP(s) will not get power from the Switch.
- Check whether the PoE output specification of the switch is compatible with the AP's PoE port or not, for example 802.3 af / 802.3at.
Note: These guidelines relate to all manufacturer PoE switches (not just ICX) and Ruckus APs.
Workaround
Apply PoE by class, class 4 for R610 model AP.Resolution
Apply PoE by class, class 4 for R610 model AP.Indoor R610 802.11ac Wave 2 3x3:3 WiFi Access Point Data Sheet:
https://ruckus-www.s3.amazonaws.com/pdf/datasheets/ds-ruckus-r610.pdf
Power Supply........................Mode Features, Max Power consumption
DC input 12V DC, 2.0A.........Full Functionality, 19.1W
802.3af.................................Limits 2.4G to 2-chain,noUSB,1Eth port, 15W
802.3at.................................Full Functionality, 18.8W