AP Power Warnings
Summary
How to solve an issue related with AP operating in reduced power mode.Question
why my AP is operating in PoE 802.3af if my switch supports 802.3at?Customer Environment
ZD 10.4.1 APs: R610Root Cause
Power supply deficiency caused by incorrect power level negotiation between the AP and the switch/PoE injectorSymptoms
When connecting the APs we can see this warning message on the ZD GUITroubleshooting Steps
From AP CLI, AP is in 802.3afrkscli: get power-mode
PoE Configured Mode : Auto
Power Consumption Status : 802.3af Switch/Injector
OK
LLDP should be enable between switch and AP, but we can see power is 24000 Watts
rkscli: get lldp
LLDP state: Enabled
LLDP interval: 30
LLDP holdtime: 120
LLDP mgmt: Enabled
LLDP bond type: Source MAC for LLDP frames on bond slaves: fixed
LLDP poe: Enabled
LLDP power: 24000
LLDP interface:
LLDP on eth0 : Enabled
LLDP on eth1 : Enabled
OK
We can try to set the power manually on AP but issue still there,
set lldp power 25000
Workaround
Rebooting AP could temporarily solve issue.Resolution
After following the procedure in the guide,https://docs.commscope.com/bundle/zd-10.4.1-userguide/page/GUID-834C099F-82ED-47DA-8C8A-B13BE4745CEA.html
the issue is resolved,
rkscli: get power-mode
PoE Configured Mode : AT
Power Consumption Status : 802.3at Switch/Injector
OK
rkscli: get lldp pse
-------------------------------------------------------------------------------
LLDP neighbors:
-------------------------------------------------------------------------------
Interface: eth0, via: LLDP, RID: 1, Time: 0 day, 00:00:15
Chassis:
ChassisID: mac d4:c1:9e:94:94:da
SysName: ICX7150-C12 Router
SysDescr: Not received
MgmtIP: 192.168.1.221
Capability: Bridge, on
Capability: Router, on
Port:
PortID: mac d4:c1:9e:94:94:db
PortDescr: GigabitEthernet1/1/2
MFS: 1522
PMD autoneg: supported: yes, enabled: yes
Adv: 10Base-T, HD: yes, FD: yes
Adv: 100Base-TX, HD: yes, FD: yes
Adv: 1000Base-T, HD: yes, FD: yes
MAU oper type: 1000BaseTFD - Four-pair Category 5 UTP, full duplex mode
MDI Power: supported: yes, enabled: yes, pair control: no
Device type: PSE
Power pairs: signal
Class: class 4
Power type: 2
Power Source: unknown
Power Priority: low
PD requested power Value: 24000
PSE allocated power Value: 26200
UPOE: 0
-------------------------------------------------------------------------------
OK
And there are no warning messages on the GUI anymore.
Related Articles
https://docs.commscope.com/bundle/zd-10.4.1-userguide/page/GUID-834C099F-82ED-47DA-8C8A-B13BE4745CEA.htmlArticle Number:
000011792
Updated:
July 15, 2021 05:30 AM (over 3 years ago)
Tags:
Performance, Configuration, Installation, Troubleshooting, ZoneDirector, ZoneFlex Indoor, ZoneFlex Outdoor
Votes:
1
This article is:
helpful
not helpful