Migration of Configuration from One SmartZone platform to other

Summary

Restoration of Configuration backup is possible only between same platform of SmartZone. The only exception is that SZ100 configuration backup can be used to restore on an SZ144 (but not vice-versa)

Question

Can we migrate or restore configuration backup from one platform of SmartZone to the other, for instance, migrating configuration from a vSZ-E to a vSZ-H, SZ-100, SZ-300 etc.?

Customer Environment

Any platform and version of SmartZone

Root Cause

Design Intent

Symptoms


 

Resolution

Following matrix explains which SmartZone platform support migration from one to the other -
 
Backup TypeSource SZ typeDestination SZ typeWhether Possible or not (Yes/No)
Configuration BackupvSZ-EvSZ-HNo
Configuration BackupvSZ-ESZ-100No
Configuration BackupvSZ-ESZ-144No
Configuration BackupvSZ-ESZ-300No
Configuration BackupvSZ-HvSZ-ENo
Configuration BackupvSZ-HSZ-100No
Configuration BackupvSZ-HSZ-144No
Configuration BackupvSZ-HSZ-300No
Configuration BackupSZ-100SZ-144Yes
Configuration BackupSZ-100vSZ-ENo
Configuration BackupSZ-100vSZ-HNo
Configuration BackupSZ-100SZ-300No
Configuration BackupSZ-144SZ-100No
Configuration BackupSZ-144vSZ-ENo
Configuration BackupSZ-144vSZ-HNo
Configuration BackupSZ-144SZ-300No
Configuration BackupSZ-300vSZ-ENo
Configuration BackupSZ-300vSZ-HNo
Configuration BackupSZ-300SZ-100No
Configuration BackupSZ-300SZ-144No
Configuration BackupvSZ-H Single InterfacevSZ-H 3 InterfaceNo
Configuration BackupvSZ-H 3 InterfacevSZ-H Single InterfaceNo

As we can in the matrix above, Restoration of Configuration backup is not possible between different platforms of SmartZone with the only exception of migration from SZ-100 to SZ-144 (but not vice-versa).

Related Articles

000010855

Article Number:
000014506

Updated:
September 24, 2024 07:20 AM (3 months ago)

Tags:
Installation, Known Issues and Workarounds, SmartCell Gateway

Votes:
0

This article is:
helpful
not helpful

Working...Please wait

This is here to prevent you from accidentally submitting twice.

The page will automatically refresh.

Alert!!

Close