Technical Support Bulletins

Technical Support Bulletin TSB-2012-011-0

Description: Under certain configurations when deployed in a NetApp Metroplex environment that utilize short wave 4G and 8G FC I/O in conjunction with 8G LW ports configured as ISL ports the Brocade 300 switch may report CRC and ENC in/out errors resulting in fabric performance degradation. This TSB describes the best practices of configuration for the Brocade 300 to reduce and eliminate this situation.
Release Date:
October 17, 2012
Edit Date:

Applicable To The Following Products

Working...Please wait

This is here to prevent you from accidentally submitting twice.

The page will automatically refresh.